e-Ultimaster Left Main sub-analysis

Overview

・1,099 patients with Left main lesions treated with Ultimaster™ DES showed acceptable clinical outcomes.

Study Design

clinical_evidence_e_ultimaster_left_main_study_design

Primary Endpoint

Target lesion failure at 1 year

・Cardiac death, target vessel MI or clinically driven target lesion revascularization

Study Outline

Patient background

Patient
characteristics
LM only
n= 514
LM + MV
n= 585
p-value
Mean age, year 69.2±11.0 68.9±10.9 P=0.65
BMI kg/m² 27.2±5.1 27.6±5.6 P=0.25
Hyperlipidaemia % 59.6 63.3 P=0.23
Diabetes, % 33.7 33.2 P=0.90
Hypertension, % 74.7 71.6 P=0.27
Previous PCI % 39.5 36.9 P=0.41
Previous CABG% 22 18 P=0.10
Patient
characteristics
LM only
n= 514
LM + MV
n= 585
p-value
Lesion longer > 25 mm % 44.8 56.1 P<0.001
Calcified 32.2 32.56 P<0.001
Num of stents/pt, n 1.4± 0.7 2.2 ±1.2 P<0.0001
Total stent length/pt, mm 30.0± 20.3 48.9± 32.2 P<0.0001
Syntax < 22 % 68.8 42.4 P<0.0001
Syntax 23-32 21.9 40.1 P=0.001
Post dilatation % 69.7 74.9 P=0.06
Radial access % 68.5 68 P=0.90
OFDI + IVUS % 36.5 27.1 P<0.01
Direct stenting % 29.4 51.3 P<0.0001

Result

clinical_evidence_e_ultimaster_primary_endopoint_result

 

Reference